Where Do VFD Harmonics Come From and How to Mitigate?

February 25, 2026
Najnowsze wiadomości firmy o Where Do VFD Harmonics Come From and How to Mitigate?

1. What Are VFD Harmonics?

 

In modern industrial automation, Variable Frequency Drives (VFDs) are essential for energy saving and precise motor control across countless applications. From conveyors and pumps to fans and compressors, VFDs regulate motor speed by varying the frequency and voltage of input power. However, despite their operational benefits, VFDs come with an inherent electrical challenge: harmonic distortion. As non-linear loads, VFDs do not draw current smoothly from the power grid. Instead, they draw current in short pulses, which introduces harmonic currents into the electrical system. These harmonics are distorted waveforms that superimpose on the fundamental frequency (50Hz or 60Hz), leading to power quality issues, increased losses, and potential equipment malfunction. At VEIKONG, we believe that understanding these distortions is the first step toward building a more efficient and reliable power system for your facility.

 

2. The Main Sources of VFD Harmonics

 

So, where exactly do these harmonics originate? To understand this, we need to look inside a typical VFD, such as the VEIKONG VFD series. The front end of most VFDs consists of a diode bridge rectifier that converts incoming AC voltage into DC voltage. This rectifier only conducts current when the instantaneous AC line voltage exceeds the voltage across the DC bus capacitors—which occurs only near the peak of the voltage waveform. As a result, the input current is not a smooth sine wave but rather a series of narrow, high-amplitude current pulses. According to Fourier analysis, these pulses are composed of the fundamental frequency and a spectrum of higher frequencies called harmonics. In a standard six-pulse rectifier, the characteristic harmonics are typically the 5th, 7th, 11th, and 13th order. Their cumulative effect can be severely disruptive to the entire electrical distribution network.

 

3. The Negative Impacts of Harmonics

 

Harmonics are not merely a theoretical concern; they have very real consequences for industrial operations. When harmonic currents flow through the electrical system, they can cause a cascade of operational issues. Common symptoms include overheating of transformers and neutral conductors due to increased losses, nuisance tripping of circuit breakers that cannot distinguish between harmonics and fault currents, and premature failure of power factor correction capacitors. For the motor itself—the very equipment the VFD is meant to control—harmonics can cause torque pulsations, increased noise, and additional heat generation, all of which reduce motor efficiency and shorten its operational lifespan. At VEIKONG, our engineering team rigorously tests every drive to ensure advanced design features that minimize these disturbances, protecting your downstream equipment and ensuring uninterrupted production.

 

4. How to Mitigate Harmonics (Part 1: Basic Solutions)

 

Mitigating harmonics effectively begins with good system design and the selection of appropriate components. For many applications, sophisticated filtering may not be immediately necessary; simpler, cost-effective measures can provide substantial improvement. The most common and straightforward method is to install a 3% or 5% AC line reactor on the input side of the VFD. This reactor increases the source impedance, smoothing out the sharp current pulses drawn by the rectifier and significantly reducing the total harmonic current distortion. Another effective approach is the use of DC chokes installed between the rectifier and the DC bus capacitors. Many VEIKONG drives come equipped with built-in DC chokes as standard, or offer optional external reactors, providing a compact and economical first line of defense against harmonics while also offering protection against input power surges.

 

5. How to Mitigate Harmonics (Part 2: Advanced Solutions)

 

For facilities with sensitive equipment or high concentrations of VFD loads, basic reactors may not be sufficient to bring harmonic distortion down to acceptable levels. In such cases, more advanced mitigation technologies are required. Passive harmonic filters, tuned to trap specific harmonic frequencies (typically the 5th and 7th), can be installed to provide a low-impedance path for those currents. Alternatively, Active Harmonic Filters (AHF) offer a more dynamic solution; they sense harmonic distortion in real-time and inject equal-but-opposite currents to actively cancel out harmonics across a wide frequency spectrum. For renewable energy applications, such as our VEIKONG Solar Pumping Inverters, we utilize advanced MPPT algorithms and optimized switching techniques that inherently produce cleaner power output, ensuring compliance with grid standards while maximizing solar energy harvest from photovoltaic arrays.

 

6. The Role of Soft Starters

 

While discussing VFDs, it is also worth noting the role of other motor control solutions. Across many industrial facilities, VEIKONG Soft Starters are used to control the acceleration of induction motors. Unlike VFDs, soft starters use phase-control thyristors to reduce voltage during startup and then switch to bypass contactors once the motor reaches full speed. During the brief starting period, soft starters can generate some harmonic distortion, although typically less severe than continuous VFD operation. However, because they are bypassed at rated speed, their overall impact on the facility's long-term harmonic profile is minimal. For applications where speed control is not required but reduced inrush current is desired, VEIKONG soft starters provide an excellent, harmonic-friendly alternative.

 

7. Conclusion and VEIKONG's Commitment

 

Understanding where VFD harmonics come from and knowing how to mitigate them is crucial knowledge for any plant manager or engineer. Whether you are using a standard VFD for conveyor control, deploying a soft starter for large pump motors, or integrating a specialized inverter for solar pumping, harmonic management is key to ensuring system longevity and operational reliability. At VEIKONG, we do not simply sell products; we provide complete drive solutions and technical expertise. Our extensive range of VFDs, soft starters, and solar inverters are engineered with harmonic mitigation as a core design principle, helping our customers worldwide achieve greener, more stable, and more efficient industrial operations. Visit our product page or contact our technical team today to find the right solution tailored to your specific application needs.